O'Hagin Fire & Ice and other low-profile roof vents

Roofs catch embers first. Low-profile roof vents keep attic air moving through a small, shielded opening instead of a tall vent cap. UC ANR's Fire Network uses O'Hagin vents as its example of this design. A 2024 California study put an installed off-ridge roof vent at about $126 and a baffled ridge vent at about $34 per foot.

TileComp shingleShakeSlateMetal
ATTIC BELOW
Price
$$$
About $100 to $200 per roof vent installed
Ember protection
Metal mesh plus a stainless ember filament
Used on
Tile, Comp shingle, Shake, Slate, Metal

Protection is RF1's read of published tests, not a lab rating. Prices are rough ranges based on a 2024 California study, not RF1 quotes.

How it works

What happens when embers hit it.

  1. 01

    The vent sits low on the roof, so wind-blown embers have less to hit.

  2. 02

    Inside, 1/8-inch metal mesh and a stainless steel filament catch embers before they reach the attic.

  3. 03

    O'Hagin says its ridge and off-ridge vents can't be tested under the standard vent test, so they comply through the roof-vent mesh path in California's 2026 code.

Why people choose it

  • Made for tile, comp shingle, shake, slate and metal roofs
  • Low profile, so it's less visible from the street
  • Keeps attic ventilation working

What to watch for

  • Most roof models aren't on the State Fire Marshal's vent listing; they comply another way
  • Roof work needs the right crew and sometimes a permit

How they work

How O'Hagin vents work

O'Hagin vents are low-profile off-ridge vents. They sit flat in the field of the roof instead of along the peak. O'Hagin designs them as a balanced system: exhaust vents go high, within 3 feet of the ridge, and intake vents go low, in the bottom third of the attic and at least 6 inches above the insulation.

Because both the intake and the exhaust are on the roof, O'Hagin says the system needs no under-eave or soffit vents. That matters for fire, because IBHS rated open-eave vents with 1/4-inch screen "Poor" at keeping embers out.

One caution from IBHS's wind tests: an off-ridge vent on the windward side of the roof pulls air in, whatever it was meant to do. So every off-ridge vent needs ember protection, not just the low ones.

Product lines

O'Hagin Fire & Ice vs standard vents

O'Hagin sells three main lines. Standard vents are for low-snow areas, and O'Hagin says they're Miami-Dade approved for winds up to 110 mph. WeatherMaster vents are for snow and ice dam areas. Fire & Ice is the line for wildfire areas.

What makes a vent Fire & Ice is the inside: 1/8-inch noncombustible, corrosion-resistant metal mesh plus O'Hagin's patented fine stainless steel wire filament, which catches embers. O'Hagin's traditional vents use 1/4-inch mesh unless upgraded, and IBHS says 1/4-inch mesh should not be used on any vent.

The finer mesh costs some airflow. On every O'Hagin data sheet we checked, the 1/8-inch version has exactly 10% less net free area than the 1/4-inch version.

O'Hagin net free area per vent, 1/4-inch vs 1/8-inch mesh
VentRoof1/4-inch mesh1/8-inch mesh (Fire & Ice)
Low Profile TaperedComp shingle, shake, slate72.00 sq in64.80 sq in
Low Profile Tapered CRSStanding seam metal78.00 sq in70.20 sq in
Low Profile FlatFlat concrete or clay tile98.75 sq in88.87 sq in
Medium ProfileM tile86.25 sq in77.63 sq in
High ProfileS tile97.50 sq in87.75 sq in
Universal Direct to DeckAll tile profiles145.80 sq in131.22 sq in

From O'Hagin's data sheets, which say the figures come from independent evaluation reports.

  • Materials: 26-gauge G90 galvanized steel (20-year warranty), or .032-inch aluminum or 16 oz copper (50-year warranty), per O'Hagin.
  • O'Hagin says its comp and metal vents can be installed below solar panels.
  • O'Hagin says Fire & Ice vents survived the Woolsey Fire on some homes, and also says the vents don't guarantee a home will survive.

Tile roofs

O'Hagin vents for tile roofs: flat, M and S tile

Tile is where O'Hagin is most different. Each tile vent is shaped to match the tile profile, so it replaces tiles instead of sticking up through them. On an S-tile roof, the vent cover takes the place of two cap tiles and one pan tile. On M and flat tile, it replaces two field tiles.

O'Hagin points out that its tile vents need no tile cutting or lead flashing, unlike dormer or eyebrow vents. If your tile roof has dormer vents now, O'Hagin doesn't make a replacement. Ember-rated dormer vents come from Vulcan and BrandGuard.

Low profile or ridge

O'Hagin low-profile vents vs a ridge vent

A ridge vent runs along the peak and only does the exhaust half of the job. O'Hagin's calculator lets a ridge vent supply 40 to 50% of the required ventilation, and the rest still has to come from low intake vents. On a short or chopped-up ridge, there may not be enough length, and the calculator switches to off-ridge vents.

O'Hagin also makes a metal ridge vent, Pitch Perfect, in its Climate-Resistant Series. O'Hagin says it qualifies for use in a roof system eligible for IBHS Wildfire Prepared Home.

In IBHS's 2017 ember tests, ridge vents with external baffles rated "Best" and generic off-ridge vents with 1/4-inch mesh rated "Poor." An off-ridge vent with louvers and steel wool fill also rated "Best." IBHS didn't name brands, so don't read that as a rating of O'Hagin. IBHS also recommended 1/8-inch metal mesh over the roof-deck opening under ridge and turbine vents.

Whichever you choose, the roofing trade group ARMA says not to mix exhaust types, like a ridge vent plus box vents, over one attic. It can short-circuit the airflow. Some building scientists disagree.

IBHS 2017 ember entry ratings for roof vents
Roof vent testedIBHS rating
Ridge vent with external baffles (Miami-Dade wind-driven-rain type)Best
Off-ridge wildfire vent with louvers and steel wool fillBest
Turbine vent, no screenGood
Ridge vent with the baffles removedFair
Generic off-ridge vent with 1/4-inch meshPoor

Wind tunnel tests from 2013 to 2014. Ember entry only, not flame. Brands not named.

How many you need

How many O'Hagin vents do you need?

O'Hagin's own vent calculator uses the California Residential Code formula. Divide the attic floor area by 150, or by 300 if the vents are split between high and low. Multiply by 144 to get square inches. Divide by the vent's net free area. Put 40 to 50% of the vents high and the rest low.

Example: an 1,800 sq ft attic in LA with vents split high and low needs 864 sq in. With Fire & Ice comp vents at 64.80 sq in each, that's 14 vents, 7 high and 7 low. Using the 1/150 ratio instead roughly doubles it, to 27 or 28 depending on the high and low split.

Prices and where to buy

O'Hagin vent prices and where to buy

O'Hagin sells mainly through roofing supply houses. It says it has over 1,000 distributors and has a distributor locator on its site. The roofing distributor QXO (formerly Beacon) lists O'Hagin comp vents.

We found no O'Hagin listing at Home Depot.

Installed, the 2024 Headwaters Economics study put an off-ridge roof vent at about $126 each, using 2023 Northern California prices.

O'Hagin retail prices we found
VentPriceWhere, when checked
Fire & Ice Low Profile Tapered comp vent, 1/8-inch mesh$45.00 to $47.38 each, by colorSuperArbor, Nov 2026 ($399 minimum order)
Fire & Ice M tile vent$59.17 to $65.00SuperArbor, Nov 2026 (flashing sold separately)

Upgrading existing vents

Retro kits for existing O'Hagin vents

If you already have standard O'Hagin vents, you may not need new ones. O'Hagin makes retro kits that turn them into Fire & Ice vents.

  • Comp shingle roofs: the CRS retro kit converts a standard Low Profile Tapered vent with 1/4-inch mesh into a Fire & Ice vent with 1/8-inch mesh. The shingles on both sides are loosened, the kit slides under the vent's tapered edge, gets nailed, and the shingles are resealed.
  • Tile roofs: the tiles and old cover come off, the existing subflashing is inspected, pre-cut 1/8-inch mesh and the stainless filament go inside it, and a new cover goes on.

Installation

What installing O'Hagin vents involves

Every install path means cutting the roof deck, lifting tile or resealing shingles. O'Hagin's instructions are written to roofing practice, and it says a bad install voids the warranty.

  • Comp, shake and slate: an 11 x 11-inch hole is cut in the deck, the flanges are sealed and fastened every 4 inches, and the roofing is woven back around the vent. The standard install is for roofs at a 3:12 pitch or steeper.
  • O'Hagin offers a wind diverter for areas with winds over 70 mph.
  • Tile: surrounding tiles come off, the subflashing goes on the deck, and the cover replaces tiles in the course, with wind clips under the course above.
  • Roof work can need a permit. Check with your building department, and include O'Hagin's data sheets if you submit plans.

Who makes it

The makers, in their own words.

O'Hagin Fire & Ice

Rohnert Park, CA

Low-profile attic vents for tile, comp shingle, shake, slate and metal roofs.

They say: Designed for superior airflow with ember protection, per O'Hagin.

Tile roofComp shingleShakeSlateMetal roof

Descriptions are each maker's claims, not RF1 test results. Before buying, confirm the exact model on the State Fire Marshal's Building Materials Listing (vents are category 8165).

See how O'Hagin compares with Vulcan, BrandGuard and Embers Out

What it costs

Roof vent, installed
$100 to $200
Ridge vent with baffle, installed
$30 to $40 per foot

Rough installed costs, based on the 2024 Headwaters Economics study. Retail, a Fire & Ice comp vent was $45 to $47 at SuperArbor in November 2026.

These are rough ranges, not RF1 quotes. Most RF1 jobs land between $500 and $5,000, and your plan prices every vent before anything is booked.

Estimate the cost for your whole house Work out how many vents your home needs

Not sure what's on your roof? Mark's drone can tell you.

Compare your mesh to real-size samples, or have Mark check every vent in person, free.

Questions

O'Hagin vent questions, answered straight.

In November 2026, one online retailer (SuperArbor) listed O'Hagin Fire & Ice comp shingle vents at $45 to $47.38 each and an M tile vent at $59 to $65, with a $399 minimum order. Installed, a 2024 California study put an off-ridge roof vent at about $126 each. Your price depends on the roof type and how many vents you need.

Don't wait for the next red flag day. Start with one call.

A free assessment, a plan with prices, and one team to do the work. Pasadena, Altadena and across Southern California.